; M7NH.ASM NorthStar Horizon with HSIO-4 overlay for MDM7xx - 11/11/83 ; ; Edit this file for your preferences then follow the "TO USE:" example ; shown below. ; ; Use the MDM7xx "SET" command to change the baudrate when desired. It ; starts out at 300 baud when the program is first called up. ; ; ; TO USE: First edit this file filling in answers for your own ; equipment. Then assemble with ASM.COM or equivalent ; assembler. Then use DDT to overlay the the results ; of this program to the original .COM file: ; ; A>DDT MDM7xx.COM ; DDT VERS 2.2 ; NEXT PC ; 4300 0100 ; -IM7NH-1.HEX (note the "I" command) ; -R ("R" loads in the .HEX file) ; NEXT PC ; 4300 0000 ; -G0 (return to CP/M) ; A>SAVE 66 MDM7xx.COM (now have a modified .COM file) ; ; = = = = = = = = = = = = = = = = = = ; ; 11/11/83 - Renamed to M7NH-1.ASM, no changes - Irv Hoff ; 09/11/83 - Changed M712HZ.ASM TO M712NS.ASM - Robert Lehman ; - Irv Hoff ; = = = = = = = = = = = = = = = = = ; BELL: EQU 07H ;bell CR: EQU 0DH ;carriage return ESC: EQU 1BH ;escape LF: EQU 0AH ;linefeed ; YES: EQU 0FFH NO: EQU 0 ; ; PORT: EQU 10H ;Port A on HSIO-4 BAUDRP: EQU PORT MODDATP: EQU PORT+2 ;data port for N*HOR MODCTL1: EQU PORT+3 ;status port for N*HOR MODRCVB: EQU 2 ;bit to test for received data MODRCVR: EQU 2 ;modem receive ready MODSNDB: EQU 1 ;bit to test for ready to send MODSNDR: EQU 1 ;modem send ready bit ; ; ; The HSIO-4 board uses the 8251 ; ; ORG 100H ; DS 3 ;(for "JMP START" instruction) ; PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H SMARTMODEM: DB NO ;yes=HAYES Smartmodem, no=non-Hayes 104H TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc. MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H ;6=2400 7=4800 8=9600 9=19200 default BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H ;default time to send character in ter- ;minal mode file transfer for slow BBS. CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H ;default time for extra wait after CRLF ;in terminal mode file transfer NOOFCOL: DB 5 ;number of DIR columns shown 10AH SETUPTST: DB YES ;yes=user-added Setup routine 10BH SCRNTEST: DB YES ;Cursor control routine 10CH ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH ;no=resend a record after a valid NAK BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH CRCDFLT: DB YES ;yes=default to CRC checking 10FH TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H CONVBKSP: DB NO ;yes=convert backspace to rub 111H TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H ADDLF: DB NO ;no=no LF after CR to send file in 113H ;terminal mode (added by remote echo) TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H TRANLOGON: DB YES ;yes=allow transmission of logon 115H ;write logon sequence at location LOGON SAVCCP: DB YES ;yes=do not overwrite CCP 116H LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H ;no=external command if EXTCHR precedes TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H LSTTST: DB YES ;yes=printer available on printer port 119H XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH ;sending a file in terminal mode XONWAIT: DB NO ;yes=wait for XON after CR while 11BH ;sending a file in terminal mode TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH EXTRA1: DB 0 ;for future expansion 11EH EXTRA2: DB 0 ;for future expansion 11FH BRKCHR: DB '@'-40H ;^@ = Send a 300 ms. break tone 120H NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H LOGCHR: DB 'L'-40H ;^L = Send logon 122H LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 125H EXTCHR: DB '^'-40H ;^^ = Send next character 126H ; ; DS 2 ; 128H ; IN$MODCTL1: IN MODCTL1 ! RET ;in modem control port 12AH DS 7 OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H DS 7 IN$MODDATP: IN MODDATP ! RET ;in modem data port 13EH DS 31 ; LOGONPTR: DW LOGON ;for user message. 160H DS 6 ; 162H JMP$GOODBYE: JMP GOODBYE ; 168H JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH RET ! NOP ! NOP ;(by-passes PMMI routine) 171H RET ! NOP ! NOP ;(by-passes PMMI routine) 174H JMP$SETUPR: JMP SETUPR ; 177H JMP$SPCLMENU: JMP SPCLMENU ; 17AH JMP$SYSVER: JMP SYSVER ; 17DH JMP$BREAK: JMP SENDBRK ; 180H ; ; ; Do not change the following six lines. ; JMP$ILPRT: DS 3 ; 183H JMP$INBUF DS 3 ; 186H JMP$INLNCOMP: DS 3 ; 189H JMP$INMODEM DS 3 ; 18CH JMP$NXTSCRN: DS 3 ; 18FH JMP$TIMER: DS 3 ; 192H ; ; CLREOS: CALL JMP$ILPRT ; 195H DB ESC,079H,0,0,0 ; 198H RET ; 19DH ; CLRSCRN: CALL JMP$ILPRT ; 19EH DB 1AH,0,0,0,0 ;clear entire screen 1A1H RET ; 1A6H ; ; SYSVER: CALL JMP$ILPRT ; 1A7H DB 'Version for NorthStar Horizon / HSIO-4 Port A' DB CR,LF,0 DB RET ;..... ; ; ;----------------------------------------------------------------------- ; ; NOTE: You can change the SYSVER message to be longer or shorter. The ; end of your last routine should terminate by 0400H (601 bytes ; available after start of SYSVER) if using the Hayes Smartmodem ; or by address 0C00H (2659 bytes available) otherwise. ; ;----------------------------------------------------------------------- ; ; YOU CAN PUT IN A MESSAGE AT THIS LOCATION WHICH CAN BE CALLED UP WITH ; CTL-O IF TRANLOGON HAS BEEN SET YES. YOU CAN PUT IN SEVERAL LINES IF ; DESIRED. END WITH A 0. ; LOGON: DB 'Hello from a NorthStar Horizon computer',CR,LF,0 ;..... ; ; ; THIS ROUTINE ALLOWS A 300 MS. BREAK TONE TO BE SEND TO RESET SOME ; TIME-SHARE COMPUTERS. ; SENDBRK: MVI A,08H ;send a break tone for 300 ms. JMP GOODBYE1 ;..... ; ; ; THIS ROUTINE SENDS A 300 MS. BREAK TONE AND SETS DTR LOW FOR THE SAME ; LENGTH OF TIME TO DISCONNECT SOME MODEMS SUCH AS THE BELL 212A, ETC. ; GOODBYE: MVI A,0AH ;set break, dtr low ; GOODBYE1: OUT MODCTL1 ;put command register out of mode IN MODCTL1 ;make sure it is now clear IN MODCTL1 ;try once more MVI B,3 ;delay for 300 ms. CALL JMP$TIMER MVI A,37H ;reset rts, flags, dtr low, enable r/t OUT MODCTL1 ;send to command register IN MODCTL1 ;clear any incoming chars. IN MODCTL1 ;try once more XRA A ;clear the 'A' reg. RET ;..... ; ; ; THE FOLLOWING ARE USED IN SETTING UP THE HSIO-4 I/O PORT A. ; INITMOD: MVI A,1 ;default transfer time to 300 baud STA MSPEED XRA A ;set rts, flags, dtr, disable r/t OUT MODCTL1 ;put command register out of mode IN MODCTL1 ;make sure it is now clear IN MODCTL1 ;try once more MVI A,0AAH OUT MODCTL1 MVI A,40H OUT MODCTL1 MVI A,4EH ;1 stop, no parity, 8 bits, 16x asynch OUT MODCTL1 ;send to mode register 1 ; INITMOD1: MVI A,06H ;start with 300 baud, internal 4 clock OUT BAUDRP ;send to baud rate port MVI A,37H ;reset rts, flags, dtr low, enable r/t OUT MODCTL1 ;send to command register IN MODCTL1 ;clear any incoming chars. IN MODCTL1 ;try once more XRA A ;clear the 'A' reg. RET ;..... ; ; ; THE FOLLOWING CHANGES THE BAUD RATE WITH THE SET COMMAND. ; SETUPR: LXI D,BAUDBUF CALL JMP$ILPRT DB 'Input Baud Rate (110, 300, 1200, 9600): ',0 CALL JMP$INBUF LXI D,BAUDBUF+2 CALL JMP$INLNCOMP DB '110',0 JNC OK110 CALL JMP$INLNCOMP ;compare baudbuf+2 with characters below DB '300',0 JNC OK300 ;go if got match CALL JMP$INLNCOMP DB '1200',0 JNC OK1200 CALL JMP$INLNCOMP DB '9600',0 JNC OK9600 CALL JMP$ILPRT ;all matches failed, ask again DB '++ Incorrect entry ++',CR,LF,BELL,0 JMP SETUPR ;try again ; OK110: MVI A,0 ;mspeed 110 baud value LHLD BD110 ;get 110 baud parameters in 'HL' JMP LOADBD ;go load them ; OK300: MVI A,1 LHLD BD300 JMP LOADBD ; OK1200: MVI A,5 LHLD BD1200 JMP LOADBD ; OK9600: MVI A,8 LHLD BD9600 ; LOADBD: STA INITMOD+1 MOV A,L ;get least significant baud rate byte STA INITMOD1+1 ;store in initmod1 JMP INITMOD ;reset n*hor hsio-4 port a ;..... ; ; ; TABLE OF BAUDRATE PARAMETERS FOR HSIO-4 BOARD I/O ; BD110: DW 0007H BD300: DW 0006H BD1200: DW 0004H BD9600: DW 0001H ; BAUDBUF: DB 10,0 DS 10 ; ;----------------------------------------------------------------------- ; ; THE FOLLOWING ROUTINE COULD BE USED TO DISPLAY SELECTIONS OF INTEREST ; TO OWNERS OF THIS COMPUTER. IF USING THE HAYES SMARTMODEM THIS IS ; UNAVAILABLE WITHOUT A SPECIAL CHANGE. ; SPCLMENU: RET ; ;----------------------------------------------------------------------- ; ; ; NOTE: MUST TERMINATE PRIOR TO 0400H (WITH SMARTMODEM) ; 0C00H (WITHOUT SMARTMODEM) ; END ; 110 ;get 110 baud parameters in 'HL' JMP LOADBD ;go load them ; OK300: MVI A,1