; M7-1HP.ASM -- Hewlett Packard overlay file for MDM7xx. 11/11/83 ; ; This overlay adapts the MDM7xx program to the HP125 Series 100. ; ; You will want to look this file over carefully. There are a number of ; options that you can use to configure the program to suit your taste. ; You use the AIDS and SOFT KEYS to configure baud rate and other para- ; meters. ; ; The HP125 uses two Z80's one for I/O and the other for crunching. ; Needless to say HP doesn't let the number crunching Z80 talk directly ; to the I/O ports, so direct communication with the ports is out. As ; luck would have it HP did include RDR: and PUN: routines, these rou- ; tines have been used in this implementation. NOTE: Special routines ; were required to device map the PUN: and RDR: to PORT 1 and to get all ; 8 bits of data in and out of the port. ; ;*********************************************************************** ; ; W A R N I N G ; - - - - - - - ; ; ALWAYS DEPART THIS PROGRAM FROM THE COMMAND LEVEL, USING THE 'BYE' ; COMMAND SO THAT YOUR HP125 GETS RECONFIGURED TO IT'S NORMAL STATE. ; ;*********************************************************************** ; ; Edit this file for your preferences then follow the "TO USE:" example ; shown below. ; ; TO USE: First edit this file filling in answers for your own ; equipment. Then assemble with ASM.COM or equivalent ; assembler. Then use DDT to overlay the the results ; of this program to the original .COM file: ; ; A>DDT MDM7xx.COM ; DDT VERS 2.2 ; NEXT PC ; 4300 0100 ; -IM7HP-1.HEX (note the "I" command) ; -R ("R" loads in the .HEX file) ; NEXT PC ; 4300 0000 ; -G0 (return to CP/M) ; A>SAVE 66 MDM7xx.COM (now have a modified .COM file) ; ; = = = = = = = = = = = = = = = = = = ; ; 11/11/83 - Renamed to M7HP-1.ASM, no changes - Irv Hoff ; 07/20/83 - Renamed to work with MDM712 - Irv Hoff ; 07/20/83 - Revised to work with HP125 - John Bingel ; 07/01/83 - Revised to work with MDM711 - Irv Hoff ; 07/01/83 - Revised to work with MDM710 - Irv Hoff ; 05/27/83 - Updated to work with MDM709 - Irv Hoff ; 05/15/83 - Revised to work with MDM708 - Irv Hoff ; 04/11/83 - Updated to work with MDM707 - Irv Hoff ; 04/04/83 - First version of this file - Irv Hoff ; ; = = = = = = = = = = = = = = = = = ; BDOS: EQU 05H BELL: EQU 07H ;bell CR: EQU 0DH ;carriage return ESC: EQU 1BH ;escape LF: EQU 0AH ;linefeed ; YES: EQU 0FFH NO: EQU 0 ; ; ; Change the following information to match your equipment ; RDRST: EQU 70FFH ;READER STATUS SFC RDRIN: EQU 03H ;READER INPUT SFC PUNOUT: EQU 04H ;PUNCH OUTPUT SFC BITS8: EQU 73FFH ;8 BIT SFC BITS7: EQU 74FFH ;RESET TO NORMAL 7 BIT SFC JVT: EQU 7EFFH ;JUMP VECTOR TABLE SFC MODRCVB: EQU 1 ;BIT TO TEST FOR RECEIVE MODRCVR: EQU 1 ;VALUE WHEN READY MODSNDB: EQU 0 ;BIT TO TEST FOR SEND MODSNDR: EQU 0 ;VALUE WHEN READY ; ORG 100H ; ; ; Change the clock speed to suit your system ; DS 3 ;(for "JMP START" instruction) ; PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H SMARTMODEM: DB NO ;yes=HAYES Smartmodem, no=non-PMMI 104H TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc. MSPEED: DB 5 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H ;6=2400 7=4800 8=9600 9=19200 default BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H ;default time to send character in ter- ;minal mode file transfer for slow BBS. CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H ;default time for extra wait after CRLF ;in terminal mode file transfer NOOFCOL: DB 5 ;number of DIR columns shown 10AH SETUPTST: DB NO ;yes=user-added Setup routine 10BH SCRNTEST: DB NO ;Cursor control routine 10CH ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH ;no=resend a record after a valid-NAK BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH CRCDFLT: DB YES ;yes=default to CRC checking 10FH TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H CONVBKSP: DB NO ;yes=convert backspace to rub 111H TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H ADDLF: DB NO ;no=no LF after CR to send file in 113H ;terminal mode (added by remote echo) TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H TRANLOGON: DB YES ;yes=allow transmission of logon 115H ;write logon sequence at location LOGON SAVCCP: DB YES ;yes=do not overwrite CCP 116H LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H ;no=external command if EXTCHR precedes TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H LSTTST: DB YES ;yes=printer available on printer port 119H XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH ;sending a file in terminal mode XONWAIT: DB NO ;yes=wait for XON after CR while 11BH ;sending a file in terminal mode TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH IGNORCTL: DB NO ;yes=CTL-chars above ^M not displayed 11DH EXTRA1: DB 0 ;for future expansion 11EH EXTRA2: DB 0 ;for future expansion 11FH BRKCHR: DB '@'-40H ;^@ = Send 300 ms. break tone 120H NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H LOGCHR: DB 'L'-40H ;^L = Send logon 122H LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H EXTCHR: DB '^'-40H ;^^ = Send next character 127H ; ; DS 2 ; 128H ; IN$MODCTL1: JMP INCTL ;in modem control port 12AH DS 7 OUT$MODDATP: JMP OUTDATA ;out modem data port 134H DS 7 IN$MODDATP: JMP INDATA ;in modem data port 13EH DS 7 ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H CPI$MODRCVR: CPI MODRCVR ! RET ;value of rcv. bit when ready 14BH ANI$MODSNDB: MVI A,MODSNDB ! RET ;bit to test for send ready 14EH CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H DS 6 ; 156H ; OUT$MODCTL1: NOP ! NOP ! RET ;out modem control port #2 15AH OUT$MODCTL2: NOP ! NOP ! RET ;out modem control port #1 15DH ; LOGONPTR: DW LOGON ;for user message. 160H DS 6 ; 162H JMP$GOODBYE: JMP GOODBYE ; 168H JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH RET ! NOP ! NOP ;(by-passes PMMI routine) 171H RET ! NOP ! NOP ;(by-passes PMMI routine) 174H JMP$SETUPR: JMP SETUPR ; 177H JMP$SPCLMENU: JMP SPCLMENU ; 17AH JMP$SYSVER: JMP SYSVER ; 17DH JMP$BREAK: JMP SENDBRK ; 180H ; ; ; Do not change the following six lines. ; JMP$ILPRT: DS 3 ; 183H JMP$INBUF DS 3 ; 186H JMP$INLNCOMP: DS 3 ; 189H JMP$INMODEM DS 3 ; 18CH JMP$NXTSCRN: DS 3 ; 18FH JMP$TIMER DS 3 ; 192H ; ; ; Routine to clear to end of screen. If using CLREOS and CLRSCRN, set ; SCRNTEST to YES at 010AH (above). ; CLREOS: CALL JMP$ILPRT ; 195H DB 0,0,0,0,0 ; 198H RET ; 19DH ; CLRSCRN: CALL JMP$ILPRT ; 19EH DB 0,0,0,0,0 ; 1A1H RET ; 1A6H ; SYSVER: LXI B,BITS8 ;SFC 115 SET PORT 1 TO 8 BITS CALL BDOS CALL JMP$ILPRT ; 1A7H ; ; ; DEVICE MAP RDR: & PUN: TO USE PORT 1 ; DB 1BH,'&i0s25d4M',1BH,'&i10s16d4M',CR,LF ; ; ; NOW PRINT LOGON ; DB 'Version for the HP125 Series 100' DB CR,LF,LF,LF,'ALWAYS SIGN OFF USING ''BYE'' FROM' DB ' THE COMMAND MODE',CR,LF,0 ; ; NOW SET UP READER ROUTINE SO WE REALLY GET 8 BITS ; LXI B,JVT ;SFC 126 LXI D,JBUF ;ADDRESS OF JUMP BUFFER CALL BDOS ;READ JUMP TABLE INTO JBUF LHLD JUMP ;GET ADDRESS RETURNED IN JBUF SHLD REAL ;AND STORE AS REAL RDRIN LXI H,INEIGHT ;GET ADDRESS OF 8 BIT INPUT SHLD JUMP ;AND STORE IN JBUF MVI A,1 ;MOVE A WRITE CODE INTO A STA FLAG ;STORE IT IN JBUF LXI B,JVT ;SFC 126 LXI D,JBUF ;ADRESS OF JUMP BUFFER CALL BDOS ;WRITE JUMP TABLE FROM JBUF RET ; ; ; MODEM I/O PRIMITIVES ; OUTDATA: PUSH B PUSH D PUSH H MOV E,A ;MOVE OUTPUT BYTE FROM A TO E MVI C,PUNOUT ;GET PUN: SFC CALL BDOS ;OUTPUT BYTE POP H POP D POP B RET ; INDATA: PUSH B PUSH D PUSH H MVI C,RDRIN ;GET RDR: SFC CALL BDOS ;GET BYTE FROM RDR: POP H POP D POP B RET ; INEIGHT: CALL READIN ;BYPASS BIT 8 STRIP IN MOV A,B ;RDR: ROUTINE RET ; INCTL: PUSH B PUSH D PUSH H LXI B,RDRST ;GET RDR: STATUS SFC CALL BDOS ;GET RDR: STATUS POP H POP D POP B RET ;..... ; ; ;----------------------------------------------------------------------- ; ; NOTE: You can change the SYSVER message to be longer or shorter. The ; end of your last routine should terminate by 0400H (601 bytes ; available after start of SYSVER) if using the Hayes Smartmodem ; or by address 0C00H (2659 bytes) otherwise. ; ;----------------------------------------------------------------------- ; ; You can put in a message at this location which can be called up with ; CTL-O if TRANLOGON has been set TRUE. You can use several lines if ; desired. End with a 0. ; LOGON: DB 'How are you today?',CR,LF,0 ;..... ; ; ; Routine to send a break tone to reset some time-share computers, if ; desired. ; SENDBRK: MVI A,02H CALL OUTDATA RET ;..... ; ; ; Routine to put DTR low (to disconnect) and/or send a break tone. ; GOODBYE: CALL JMP$ILPRT DB 1BH,'E',0 ;COLD BOOT SYSTEM RET ;..... ; ; READIN: DB 0C3H ;JUMP OPCODE REAL: DS 2 ;SAVE 2 BYTES FOR ADDRESS JVN: DB 7 ;READER BIOS CODE FLAG: DB 0 ;READ/WRITE CODE OPCODE: DS 1 ;RESERVE 1 BYTE FOR JMP CODE JUMP: DS 2 ;AND 2 BYTES FOR ADDRESS JBUF: EQU JVN ;NAME ENTIRE BUFFER JBUF ; ;..... ; ; ; You can use this area for any special initialization or setup you may ; wish to include. Each must stop with a RET. You can check the other ; available overlays for ideas how to write your own routines if that ; may be of some help. ; INITMOD: RET ; SETUPR: RET ; ; ; If using the Hayes Smartmodem this is unavailable without a special ; change. ; SPCLMENU: RET ; ; ; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem) ; 0C00H (without Smartmodem) ;..... ; END ;  time-share computers, if ; desired. ; SENDBRK: MVI A,