; M7NS-2.ASM -- North Star HORIZON overlay (right serial). 06/01/84 ; ; *** Be sure your right serial port header is strapped for 1200 baud!!! ; ; You will want to look this file over carefully. There are a number of ; options that you can use to configure the program to suit your taste. ; ; Edit this file for your preferences then follow the "TO USE:" example ; shown below. ; ; TO USE: First edit this file filling in answers for your own ; equipment. Then assemble with ASM.COM or equivalent ; assembler. Then use DDT to overlay the the results ; of this program to the original .COM file: ; ; A>DDT MDM712.COM ; DDT VERS 2.2 ; NEXT PC ; 4x00 0100 ; -IM7NS-2.HEX (note the "I" command) ; -R ("R" loads in the .HEX file) ; NEXT PC ; 4x00 0000 ; -G0 (return to CP/M) ; A>SAVE 73 MDM7xx.COM (now have a modified .COM file) ; ^ ; This may vary with version of MDM7xx used. ; ; = = = = = = = = = = = = = = = = = = ; ;06/01/84 - Revised save values - Dennis Recla ;11/27/83 - Renamed M7NS-1 no changes - S. Kluger ;09/05/83 - Constructed from M712GP - Sigi Kluger ; ; = = = = = = = = = = = = = = = = = ; BELL: EQU 07H ;bell CR: EQU 0DH ;carriage return ESC: EQU 1BH ;escape LF: EQU 0AH ;linefeed ; YES: EQU 0FFH NO: EQU 0 ; ; ; Change the following information to match your equipment ; PORT: EQU 4 MODCTL1: EQU PORT+1 ;MODEM CONTROL PORT MODDATP: EQU PORT ;MODEM DATA IN PORT MODDATO: EQU PORT ;MODEM DATA OUT PORT MODDCDB: EQU 4 ;CARRIER DETECT BIT MODDCDA: EQU 0 ;VALUE WHEN ACTIVE BAUDRP: EQU PORT+1 ;BAUD RATE PORT MODCTL2: EQU PORT+1 ;2ND MODEM CONTROL PORT MODRCVB: EQU 2 ;BIT TO TEST FOR RECEIVE MODRCVR: EQU 2 ;VALUE WHEN READY MODSNDB: EQU 1 ;BIT TO TEST FOR SEND MODSNDR: EQU 1 ;VALUE WHEN READY ; ORG 100H ; ; ; Change the clock speed to suit your system ; DS 3 ;(for "JMP START" instruction) ; PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H SMARTMODEM: DB YES ;yes=HAYES Smartmodem, no=non-PMMI 104H TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc. MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H ;6=2400 7=4800 8=9600 9=19200 default BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H ;default time to send character in ter- ;minal mode file transfer for sloW BBS. CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H ;default time for extra wait after CRLF ;in terminal mode file transfer NOOFCOL: DB 5 ;number of DIR columns shown 10AH SETUPTST: DB YES ;yes=user-added Setup routine 10BH SCRNTEST: DB NO ;Cursor control routine 10CH ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH ;no=resend a record after a valid-NAK BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH CRCDFLT: DB YES ;yes=default to CRC checking 10FH TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H CONVBKSP: DB NO ;yes=convert backspace to rub 111H TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H ADDLF: DB NO ;no=no LF after CR to send file in 113H ;terminal mode (added by remote echo) TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H TRANLOGON: DB YES ;yes=allow transmission of logon 115H ;write logon sequence at location LOGON SAVCCP: DB YES ;yes=do not overwrite CCP 116H LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H ;no=external command if EXTCHR precedes TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H LSTTST: DB YES ;yes=printer available on printer port 119H XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH ;sending a file in terminal mode XONWAIT: DB NO ;yes=wait for XON after CR while 11BH ;sending a file in terminal mode TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH EXTRA1: DB 0 ;for future expansion 11EH EXTRA2: DB 0 ;for future expansion 11FH BRKCHR: DB '@'-40H ;^@ = Send 300 ms. break tone 120H NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H LOGCHR: DB 'L'-40H ;^L = Send logon 122H LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H EXTCHR: DB '^'-40H ;^^ = Send next character 127H ; ; DS 2 ; 128H ; IN$MODCTL1: IN MODCTL1 ! RET ;in modem control port 12AH DS 7 OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H DS 7 IN$MODDATP: IN MODDATP ! RET ;in modem data port 13EH DS 7 ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H CPI$MODRCVR: CPI MODRCVR ! RET ;value of rcv. bit when ready 14BH ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H DS 6 ; 156H ; OUT$MODCTL1: OUT MODCTL1 ! RET ;out modem control port #2 15AH OUT$MODCTL2: OUT MODCTL2 ! RET ;out modem control port #1 15DH ; LOGONPTR: DW LOGON ;for user message. 160H DS 6 ; 162H JMP$GOODBYE: JMP GOODBYE ; 168H JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH RET ! NOP ! NOP ;(by-passes PMMI routine) 171H RET ! NOP ! NOP ;(by-passes PMMI routine) 174H JMP$SETUPR: JMP SETUPR ; 177H JMP$SPCLMENU: JMP SPCLMENU ; 17AH JMP$SYSVER: JMP SYSVER ; 17DH JMP$BREAK: JMP SENDBRK ; 180H ; ; ; Do not change the following six lines. ; JMP$ILPRT: DS 3 ; 183H JMP$INBUF DS 3 ; 186H JMP$INLNCOMP: DS 3 ; 189H JMP$INMODEM DS 3 ; 18CH JMP$NXTSCRN: DS 3 ; 18FH JMP$TIMER DS 3 ; 192H ; ; ; Routine to clear to end of screen. If using CLREOS and CLRSCRN, set ; SCRNTEST to YES at 010AH (above). ; CLREOS: CALL JMP$ILPRT ; 195H DB 0,0,0,0,0 ; 198H RET ; 19DH ; CLRSCRN: CALL JMP$ILPRT ; 19EH DB 0,0,0,0,0 ; 1A1H RET ; 1A6H ; SYSVER: CALL JMP$ILPRT ; 1A7H DB 'North Star HORIZON' DB CR,LF,0 RET ;..... ; ; ;----------------------------------------------------------------------- ; ; NOTE: You can change the SYSVER message to be longer or shorter. The ; end of your last routine should terminate by 0400H (601 bytes ; available after start of SYSVER) if using the Hayes Smartmodem ; or by address 0C00H (2659 bytes) otherwise. ; ;----------------------------------------------------------------------- ; ; You can put in a message at this location which can be called up with ; CTL-O if TRANLOGON has been set TRUE. You can use several lines if ; desired. End with a 0. ; LOGON: DB 'How are you today?',CR,LF,0 ;..... ; ; ; Add your own routine here to send a break tone to reset some time-share ; computers, if desired. ; SENDBRK: RET ;..... ; ; ; Add your own routine here to put DTR low and/or send a break tone. ; Check other routines such as MDM709DP.ASM which is using this feature. ; GOODBYE: RET ;..... ; ; ; You can use this area for any special initialization or setup you may ; wish to include. Each must stop with a RET. You can check the other ; available overlays for ideas how to write your own routines if that ; may be of some help. ; INITMOD: MVI A,1 STA MSPEED MVI A,40H ;RESET USART OUT MODCTL1 INITMOD2: MVI A,01001111B ;1STOP,64XCLK,8BIT,NO PAR OUT MODCTL1 MVI A,37H OUT MODCTL1 IN MODDATP RET ; ; ; Setup routine to allow changing modem speed with the SET command. ; SETUPR: LXI D,BAUDBUF ;POINT TO NEW INPUT BUFFER CALL JMP$ILPRT DB 'Input Baud Rate (300, 1200): ',0 CALL JMP$INBUF LXI D,BAUDBUF+2 CALL JMP$INLNCOMP ;COMPARE BAUDBUF+2 WITH CHARACTERS BELOW DB '300',0 JNC OK300 ;GO IF GOT MATCH CALL JMP$INLNCOMP DB '1200',0 JNC OK1200 CALL JMP$ILPRT ;ALL MATCHES FAILED, TELL OPERATOR DB '++ Incorrect entry ++',CR,LF,BELL,0 JMP SETUPR ;TRY AGAIN ; OK300: MVI A,1 LHLD BD300 JMP LOADBD ; OK1200: MVI A,5 LHLD BD1200 JMP LOADBD ; LOADBD: STA INITMOD+1 ;CHANGE TIME-TO-SEND TO MATCH BAUDRATE MOV A,L ;GET BAUDRATE BYTE STA INITMOD2+1 ;SEND TO USART FOR NEW BAUDRATE JMP INITMOD ;REINITIALIZE TO NEW BAUDRATE, THEN DONE ; ; ; TABLE OF BAUDRATE PARAMETERS ; BD300: DW 01001111B BD1200: DW 01001110B ; BAUDBUF: DB 10,0 DS 10 ; ; ; If using the Hayes Smartmodem this is unavailable without a special ; change. ; SPCLMENU: RET ; ; ; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem) ; 0C00H (without Smartmodem) ;..... ; END ;